Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add filters

Language
Document Type
Year range
1.
International Journal of Multiphase Flow ; : 104422.0, 2023.
Article in English | ScienceDirect | ID: covidwho-2238931

ABSTRACT

The spread of the COVID-19 pandemic is mainly due to the direct transmission routes of SARS-CoV-2 virus-carrying aerosols in indoor environments. In this study, the effect of indoor relative humidity (RH∞) on the number concentration, size distribution, and trajectory of sneeze droplets was studied in a confined space experimentally and numerically. Computational fluid dynamics (CFD) simulations using the renormalization group k-ε turbulence model by considering the one-way and two-way (humidity) coupling models were performed to assess the effects of humidity fields on the propagation of droplets. Number concentration profiles indicated that the RH∞ affected the dispersion modes of droplets differently for the puff, droplet cloud, fully-dispersed, and dilute-dispersed droplets phases identified by the shadowgraph imaging technique. The two-way (humidity) coupling model led to a close agreement with the experimental data in all phases. In particular, the two-way coupling provided better agreement with the data in the puff phase compared to the one-way coupling model. However, the one-way coupling model was sufficient for studying the motion of airborne droplets in the other phases. The velocity fields in the droplet cloud were more sensitive to RH∞ than the puff and fully-dispersed droplets phases. Also, the effect of RH∞ on the maximum spreading distance of droplets, dmax,sp, in the puff was insignificant, while its effect became dominant in the dilute-dispersed droplets phase. A dynamic change in the velocity profile of the sneeze jet was seen at a critical relative humidity RH∞,crit of about 48%. At RH∞< RH∞,crit, the number concentration of aerosolized droplets increases, significantly affecting the size distribution and the velocity of droplets. At RH∞≥ RH∞,crit, the effect of evaporation time on the number concentration, and diameter of droplets was negligible. At RH∞ of 24 and 64%, dmax,sp was 2.14 m (7 feet) and 3.05 m (10 feet), respectively. However, a dry indoor environment led to an increase in evaporation rate and more than four times number concentration of aerosolized droplets compared to a humid environment. Thus, the risk of direct transmission of Covid-19 in a humid indoor environment was higher than the dry conditions, which suggested the requirements for incorporating the RH∞ effect in the social distancing guideline.

2.
Environ Sci Pollut Res Int ; 30(15): 44067-44085, 2023 Mar.
Article in English | MEDLINE | ID: covidwho-2209479

ABSTRACT

Effects of indoor temperature (T∞) and relative humidity (RH∞) on the airborne transmission of sneeze droplets in a confined space were studied over the T∞ range of 15-30 °C and RH∞ of 22-62%. In addition, a theoretical evaporation model was used to estimate the droplet lifetime based on experimental data. The results showed that the body mass index (BMI) of the participants played an important role in the sneezing jet velocity, while the impact of the BMI and gender of participants was insignificant on the size distribution of droplets. At a critical relative humidity RH∞,crit of 46%, the sneezing jet velocity and droplet lifetime were roughly independent of T∞. At RH∞ < RH∞,crit, the sneezing jet velocity decreased by increasing T∞ from 15 to 30 °C, while its trend was reversed at RH∞ > RH∞,crit. The maximum spreading distance of aerosols increased by decreasing the RH∞ and increasing T∞, while the droplet lifetime increased by decreasing T∞ at RH∞ > RH∞,crit. The mean diameter of aerosolized droplets was less affected by T∞ than the large droplets at RH∞ < RH∞,crit, while the mean diameter and number fraction of aerosols were more influenced by RH∞ than the T∞ in the range of 46% ≤ RH∞ ≤ 62%. In summary, this study suggests suitable indoor environmental conditions by considering the transmission rate and lifetime of respiratory droplets to reduce the spread of COVID-19.


Subject(s)
COVID-19 , Humans , Respiratory Aerosols and Droplets , Confined Spaces , Sneezing , Particle Size
3.
Sci Total Environ ; 858(Pt 2): 159444, 2023 Feb 01.
Article in English | MEDLINE | ID: covidwho-2069674

ABSTRACT

The spread of the COVID-19 pandemic through the airborne transmission of coronavirus-containing droplets emitted during coughing, sneezing, and speaking has now been well recognized. This study presented the effect of indoor temperature (T∞) on the airflow dynamics, velocity fields, size distribution, and airborne transmission of sneeze droplets in a confined space through experimental investigation and computational fluid dynamic (CFD) modeling. The CFD simulations were performed using the renormalization group k-ε turbulence model. The experimental shadowgraph imaging and CFD simulations showed the time evolution of sneeze droplet concentrations into the turbulent expanded puff, droplet cloud, and fully-dispersed droplets. Also, the predicted mean velocity of droplets was compared with the obtained experimental data to assess the accuracy of the results. In addition, the validated computational model was used to study the sneeze complex airflow behavior and airborne transmission of small, medium, and large respiratory droplets in confined spaces at different temperatures. The warm room showed more than ∼14 % increase in airborne aerosols than the room with a mild temperature. The study provides information on the effect of room temperature on the evaporation of respiratory droplets during sneezing. The findings of this fundamental study may be used in developing exposure guidelines by controlling the temperature level in indoor environments to reduce the exposure risk of COVID-19.


Subject(s)
COVID-19 , Sneezing , Humans , Temperature , Pandemics , Respiratory Aerosols and Droplets
SELECTION OF CITATIONS
SEARCH DETAIL